- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Tesoro SLC Cogeneration Plant: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Tesoro SLC Cogeneration Plant
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 75% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2004
- Net generation, 2025
- 198,679 MWh
- Grid
- 138 kV, 46 kV, 14 kV to PacifiCorp (PACE)
- Location
- Salt Lake County, Utah
- Operated by
- Tesoro Refng Marketing Co Mntn Region
Operations
- Net generation, 2025
- 198,679
MWh - Fuel burned, 2025
- 2,218,889
MMBtu - Capacity factor, 2025
- 74.6
% - Heat rate, 2025
- 11,168
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 133,896 | 1,500,452 | — | 11,206 |
| 2025 | 198,679 | 2,218,889 | 74.6% | 11,168 |
| 2024 | 185,084 | 2,114,925 | 69.3% | 11,427 |
| 2023 | 139,310 | 1,506,771 | 52.3% | 10,816 |
| 2022 | 202,634 | 2,281,896 | 76.1% | 11,261 |
| 2021 | 197,428 | 2,244,798 | 74.1% | 11,370 |
| 2020 | 186,685 | 2,126,764 | 69.9% | 11,392 |
| 2019 | 194,753 | 2,270,996 | 73.1% | 11,661 |
| 2018 | 182,165 | 2,074,765 | 68.4% | 11,390 |
| 2017 | 195,031 | 2,292,024 | 73.2% | 11,752 |
| 2016 | 194,170 | 2,415,000 | 72.7% | 12,438 |
| 2015 | 177,031 | 1,806,020 | 66.5% | 10,202 |
| 2014 | 180,105 | 2,055,881 | 67.6% | 11,415 |
| 2013 | 156,391 | 1,895,494 | 58.7% | 12,120 |
| 2012 | 158,727 | 1,975,970 | 59.4% | 12,449 |
| 2011 | 173,538 | 2,038,310 | 65.2% | 11,746 |
| 2010 | 183,900 | 2,159,937 | 69.1% | 11,745 |
| 2009 | 192,831 | 2,187,018 | 72.4% | 11,342 |
| 2008 | 180,583 | 2,081,013 | 67.6% | 11,524 |
| 2007 | 40,986 | 3,471,161 | 15.4% | — |
| 2006 | 175,245 | 2,927,472 | 65.8% | 16,705 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.