- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Tolk: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Tolk
Power plant · Coal
Key facts
Power plant · Coalran 29% of 2025 Retiring- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1982
- Net generation, 2025
- 2,911,290 MWh
- Grid
- 230 kV to Southwestern Public Service Co (SWPP)
- Location
- Lamb County, Texas
- Operated by
- Southwestern Public Service Co
Output
- Gas
- Coal
Details
Who’s behind it
- Owner
- Xcel Energy
Interested in this project?
Set an alert Book a call Join the beta
Our team gets you what you need.
Beta: private project space · data room · readiness check
- Technology
- Coal source: “Conventional Steam Coal”
- Age
- 44 years since 1982
- Heat rate
- 11,383 Btu/kWh 2025
All 7 attributes from EIA-860M Preliminary Monthly Electric Generator Inventory
| Attribute | Value |
|---|---|
| Gem |
|
| EPA greenhouse gas reporting (GHGRP) |
|
| Fuel burned (MMBtu), 2025 | 33,139,575 |
| Capacity factor, 2025 | 0.293 |
| Heat rate (Btu/kWh), 2025 | 11,383.1 |
| Net generation (MWh), 2025 | 2,911,290.0 |
| Balancing authority code | SWPP |
Retirement
EIA-860M September 2026StatusAt least half of the plant's in-service nameplate capacity is scheduled to retire, on dates its owner has reported to EIA. As of EIA-860M for September 2026.- Next scheduled retirement
- December 2028
- Capacity scheduled to retire
- 1,135.8 MW
- Generators scheduled to retire
- 2
- Share of in-service capacity scheduled
- 100%
- Capacity still in service
- 1,135.8 MW
| Generator | Technology | Nameplate | State | Date |
|---|---|---|---|---|
| 1 | Conventional Steam Coal | 567.9 MW | Scheduled to retire | December 2028 |
| 2 | Conventional Steam Coal | 567.9 MW | Scheduled to retire | December 2028 |
Grid
EIA-860 2025Grid fieldsAs the plant reported them to EIA-860 for 2025 (Schedule 2).- Grid voltage at the plant
- 230 kV
- Transmission or distribution system owner
- Southwestern Public Service Co
- Balancing authority
- Southwest Power Pool
- NERC region
- MRO
Transmission lines within 25 km (10)
- 230 kV line (OSM way 164252426)
- 230 kV line (OSM way 1286672722)
- 230 kV line (OSM way 164252425)
- 230 kV line (OSM way 1286672730)
- 230 kV line (OSM way 1286672729)
- 345 kV line (OSM way 1256512905)
- 230 kV line (OSM way 1286672724)
- 230 kV line (OSM way 1286672721)
- 230 kV line (OSM way 1286672723)
- Eddy Acdcac Tie 345 kV line
Can the connection be reused?
A plant that retires usually leaves its substation, transmission connection and interconnection agreement behind, and those may be reusable by a new project at the same site. FERC Order No. 845 lets an interconnection customer use surplus interconnection service at an existing site, and some transmission providers' tariffs let a replacement resource take over a retiring unit's interconnection service, usually within a set time after the retirement. Whether any such right still exists here, who holds it and on what terms depends on the owner, the transmission provider and timing; this page does not establish any of that.
Ownership
2 companies2| Company | Role | Share | As of | Source |
|---|---|---|---|---|
| Southwestern Public Service Co | Operator | EIA-860M | ||
| Xcel Energy | Owner | 100.0% | 31 Dec 2023 | EPA GHGRP |
Timeline
- Stated Units 1, 2 scheduled to retire, 1,135.8 MW · EIA-860M
- In service · EIA-860M
Sources
7 sourcesSources EIA-860M · GEM · OpenStreetMap · LBNL · EIA · EIA-860M Preliminary Monthly Electric Generator Inventory · EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)
© OpenStreetMap contributors
Sources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- Global Energy Monitor — Global Integrated Power Tracker (unit-level power plants, eight technologies, all statuses)Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- OpenStreetMap power network, US — transmission lines and cables (69 kV and up, or voltage not tagged) and substations, from Geofabrik's US state extracts© OpenStreetMap contributors. Power lines, cables and substations filtered and reshaped by Inframation from the OpenStreetMap elements in Overture Maps' base/infrastructure theme; this derived database is available under the Open Database License 1.0 as GeoParquet files at https://tiles.inframation.io/grid/osm-power/ (latest.json names the current version's files; licence: https://www.openstreetmap.org/copyright)
- LBNL — A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024 (OEDI submission 8742)Yin, Nait Belaid & Heleno (2026), Lawrence Berkeley National Laboratory, OEDI, CC BY 4.0: A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024. Modified by Inframation: HIFLD-side fields only, names re-cased, coordinates rounded.
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)
- EIA-860M Preliminary Monthly Electric Generator Inventory
- EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)