Tulsa
Power plant · Gas, steam turbine
Key facts
Power plant · Gas, steam turbineran 10% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1956
- Net generation, 2025
- 295,016 MWh
- Grid
- 138 kV to Public Service Co of Oklahoma (SWPP)
- Location
- Tulsa County, Oklahoma
- Operated by
- Public Service Co of Oklahoma
Output
- Gas
- Oil
Details
Who’s behind it
Interested in this project?
Set an alert Book a call Join the beta
Our team gets you what you need.
Beta: private project space · data room · readiness check
- Technology
- Gas, steam turbine source: “Natural Gas Steam Turbine”
- Age
- 70 years since 1956
- Unused energy
- 2,755 GWh 2025Unused energyA lead, not a guarantee: MW × hours × (1 − capacity factor) for the latest year (EIA-923), gas, coal and oil plants only. Air-permit run-hour caps, heat rate (cost to run) and capacity-market or reliability obligations can rule it out.
- Heat rate
- 13,196 Btu/kWh 2025
All 6 attributes from EIA-860M Preliminary Monthly Electric Generator Inventory
| Attribute | Value |
|---|---|
| EPA greenhouse gas reporting (GHGRP) |
|
| Fuel burned (MMBtu), 2025 | 3,893,063 |
| Capacity factor, 2025 | 0.097 |
| Heat rate (Btu/kWh), 2025 | 13,196.1 |
| Net generation (MWh), 2025 | 295,016 |
| Balancing authority code | SWPP |
Retirement
EIA-860M September 2026StatusSome generators have retired; the rest of the plant is still in service. As of EIA-860M for September 2026.- Capacity retired
- 95 MW
- Generators retired
- 1
- Capacity still in service
- 348.2 MW
| Generator | Technology | Nameplate | State | Date |
|---|---|---|---|---|
| 3 | Natural Gas Steam Turbine | 95 MW | Retired | February 2012 |
Grid
EIA-860 2025Grid fieldsAs the plant reported them to EIA-860 for 2025 (Schedule 2).- Grid voltage at the plant
- 138 kV
- Transmission or distribution system owner
- Public Service Co of Oklahoma
- Balancing authority
- Southwest Power Pool
- NERC region
- MRO
Transmission lines within 25 km (10)
- Sand Springs Substation 138 kV line
- Riverside 138 kV line
- Tulsa Southeast 138 kV line
- Sapulpa Road 138 kV line
- Riverside 138 kV line
- Sand Springs Substation - Sapulpa Road 138 kV
- Sapulpa Road 138 kV line
- Tulsa Southeast - South Hudson Substaion 138 kV
- South Hudson Substaion 138 kV line
- Sapulpa Road 138 kV line
Can the connection be reused?
A plant that retires usually leaves its substation, transmission connection and interconnection agreement behind, and those may be reusable by a new project at the same site. FERC Order No. 845 lets an interconnection customer use surplus interconnection service at an existing site, and some transmission providers' tariffs let a replacement resource take over a retiring unit's interconnection service, usually within a set time after the retirement. Whether any such right still exists here, who holds it and on what terms depends on the owner, the transmission provider and timing; this page does not establish any of that.
Ownership
2 companies2| Company | Role | Share | As of | Source |
|---|---|---|---|---|
| Public Service Co of Oklahoma | Operator | EIA-860M | ||
| AMERICAN ELECTRIC POWER CO INC | Owner | 100.0% | 31 Dec 2023 | EPA GHGRP |
Timeline
- Stated Unit 3 scheduled to retire, 95 MW · EIA-860M
- In service · EIA-860M
Sources
5 sourcesSources EIA-860M · LBNL · EIA · EIA-860M Preliminary Monthly Electric Generator Inventory · EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)
Sources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- LBNL — A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024 (OEDI submission 8742)Yin, Nait Belaid & Heleno (2026), Lawrence Berkeley National Laboratory, OEDI, CC BY 4.0: A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024. Modified by Inframation: HIFLD-side fields only, names re-cased, coordinates rounded.
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)
- EIA-860M Preliminary Monthly Electric Generator Inventory
- EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)
Around this plant
Nearby
within 25 km| Project | Kind | Away | MW |
|---|---|---|---|
| BP AMOCO / 512 S CINCINNATI AVE SHARED SERVICE CE Built | Large load | 4.0 km | |
| DXC TECHNOLOGY SERVICES LLC / DXC TECHNOLOGY SERVICES LLC Built | Large load | 14.8 km | |
| DXC TECHNOLOGY SERVICES LLC / CHEROKEE DATA CENTER Built | Large load | 17.8 km | |
| DC1 Data Center Filed | Large load | 18.2 km |