- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Tulsa: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Tulsa
Power plant · Gas, steam turbine
Key facts
Power plant · Gas, steam turbineran 10% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1956
- Net generation, 2025
- 295,016 MWh
- Grid
- 138 kV to Public Service Co of Oklahoma (SWPP)
- Location
- Tulsa County, Oklahoma
- Operated by
- Public Service Co of Oklahoma
Operations
- Net generation, 2025
- 295,016
MWh - Fuel burned, 2025
- 3,893,063
MMBtu - Capacity factor, 2025
- 9.7
% - Heat rate, 2025
- 13,196
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 295,016 | 3,893,063 | 9.7% | 13,196 |
| 2024 | 384,535 | 4,990,150 | 12.6% | 12,977 |
| 2023 | 214,317 | 2,846,006 | 7.0% | 13,279 |
| 2022 | 262,027 | 3,604,454 | 8.6% | 13,756 |
| 2021 | 171,446 | 2,429,544 | 5.6% | 14,171 |
| 2020 | 232,045 | 3,434,207 | 7.6% | 14,800 |
| 2019 | 333,257 | 4,663,467 | 10.9% | 13,994 |
| 2018 | 431,029 | 5,557,399 | 14.1% | 12,893 |
| 2017 | 248,112 | 3,527,315 | 8.1% | 14,217 |
| 2016 | 237,953 | 3,525,686 | 7.8% | 14,817 |
| 2015 | 223,590 | 3,353,857 | 7.3% | 15,000 |
| 2014 | 196,858 | 2,946,163 | 6.5% | 14,966 |
| 2013 | 191,889 | 2,971,533 | 6.3% | 15,486 |
| 2012 | 236,529 | 3,696,965 | 7.7% | 15,630 |
| 2011 | 266,175 | 4,164,247 | 8.7% | 15,645 |
| 2010 | 254,150 | 4,016,486 | 8.3% | 15,804 |
| 2009 | 192,562 | 3,039,512 | 6.3% | 15,785 |
| 2008 | 240,131 | 3,710,771 | 7.8% | 15,453 |
| 2007 | 368,644 | 5,137,980 | 12.1% | 13,938 |
| 2006 | 429,485 | 5,662,835 | 14.1% | 13,185 |
| 2005 | 528,976 | 6,627,602 | 17.3% | 12,529 |
| 2004 | 278,980 | 3,744,737 | 9.1% | 13,423 |
| 2003 | 411,174 | 5,290,738 | 13.5% | 12,867 |
| 2002 | 214,917 | 2,630,630 | 7.0% | 12,240 |
| 2001 | 264,949 | 3,085,689 | 8.7% | 11,646 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.