- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Warner Lambert: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Warner Lambert
Power plant · Oil
Key facts
Power plant · Oilran 22% of 2025 Standby- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1989
- Net generation, 2025
- 24,329 MWh
- Grid
- 40 kV to DTE Electric Company (MISO)
- Location
- Washtenaw County, Michigan
- Operated by
- University of Michigan NCampus ResearchSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 24,329
MWh - Fuel burned, 2025
- 434,799
MMBtu - Capacity factor, 2025
- 22.4
% - Heat rate, 2025
- 17,872
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 16,554 | 298,350 | — | 18,023 |
| 2025 | 24,329 | 434,799 | 22.4% | 17,872 |
| 2024 | 23,206 | 414,132 | 21.3% | 17,846 |
| 2023 | 19,335 | 342,751 | 17.8% | 17,727 |
| 2022 (11 of 12 months) | 20,857 | 324,336 | — | 15,550 |
| 2021 (10 of 12 months) | 19,564 | 281,154 | — | 14,371 |
| 2020 | 24,166 | 341,582 | 22.2% | 14,135 |
| 2019 | 23,802 | 337,747 | 21.9% | 14,190 |
| 2018 | 25,002 | 350,145 | 23.0% | 14,005 |
| 2017 | 24,468 | 350,159 | 22.5% | 14,311 |
| 2016 | 24,967 | 355,061 | 22.9% | 14,221 |
| 2015 | 25,015 | 362,837 | 23.0% | 14,504 |
| 2014 | 24,315 | 367,483 | 22.4% | 15,114 |
| 2013 | 5,935 | 89,376 | 5.5% | 15,059 |
| 2012 | 24 | 91 | 0.0% | — |
| 2011 | 10 | 72 | 0.0% | 7,200 |
| 2010 | 28 | 236 | 0.0% | 8,429 |
| 2009 | 33 | 366 | 0.0% | 11,091 |
| 2008 | 58 | 724 | 0.1% | 12,483 |
| 2007 | 1,162 | 21,250 | 1.1% | 18,287 |
| 2006 | 459 | 6,963 | 0.4% | 15,181 |
| 2005 | 25,533 | 316,172 | 23.5% | 12,383 |
| 2004 | 24,747 | 374,587 | 22.7% | 15,137 |
| 2002 | 22,667 | 328,331 | 20.9% | 14,485 |
| 2001 | 25,047 | 828,772 | 23.1% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.