Cardinal Cogen
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 85% of 2014 Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1987
- Net generation, 2014
- 394,299 MWh
- Location
- Santa Clara County, California
- Operated by
- Cardinal Cogen Inc
Output
- Gas
- Unspecified fuel
Details
Who’s behind it
- Owner
- General Electric CO
Interested in this project?
Set an alert Book a call Join the beta
Our team gets you what you need.
Beta: private project space · data room · readiness check
- Technology
- Gas, combined cycle source: “Natural Gas Fired Combined Cycle”
- Age
- 39 years since 1987
All 2 attributes from EIA-860M Preliminary Monthly Electric Generator Inventory
| Attribute | Value |
|---|---|
| EPA greenhouse gas reporting (GHGRP) |
|
| Balancing authority code | CISO |
Retirement
EIA-860M September 2026StatusEvery generator EIA lists at this plant has retired. As of EIA-860M for September 2026.- Retired
- March 2015
- Capacity retired
- 52.8 MW
- Generators retired
- 2
| Generator | Technology | Nameplate | State | Date |
|---|---|---|---|---|
| GTG1 | Natural Gas Fired Combined Cycle | 42.1 MW | Retired | March 2015 |
| STG1 | Natural Gas Fired Combined Cycle | 10.7 MW | Retired | March 2015 |
Grid
EIA-860Grid fieldsAs the plant reported them to EIA-860 (Schedule 2).- Balancing authority
- CISO
Transmission lines within 25 km (10)
Connection points within 25 km (1)
Can the connection be reused?
A plant that retires usually leaves its substation, transmission connection and interconnection agreement behind, and those may be reusable by a new project at the same site. FERC Order No. 845 lets an interconnection customer use surplus interconnection service at an existing site, and some transmission providers' tariffs let a replacement resource take over a retiring unit's interconnection service, usually within a set time after the retirement. Whether any such right still exists here, who holds it and on what terms depends on the owner, the transmission provider and timing; this page does not establish any of that.
Ownership
2 companies2| Company | Role | Share | As of | Source |
|---|---|---|---|---|
| Cardinal Cogen Inc | Operator | EIA-860M | ||
| GENERAL ELECTRIC CO | Owner | 100.0% | Dec 31, 2023 | EPA GHGRP |
Timeline
- Stated Units GTG1, STG1 scheduled to retire, 52.8 MW · EIA-860M
- In service · EIA-860M
Sources
6 sourcesSources EIA-860M · LBNL · CAISO · EIA · EIA-860M Preliminary Monthly Electric Generator Inventory · EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)
Sources
- EIA-860M
- LBNLYin, Nait Belaid & Heleno (2026), Lawrence Berkeley National Laboratory, OEDI, CC BY 4.0: A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024. Modified by Inframation: HIFLD-side fields only, names re-cased, coordinates rounded.
- CAISOSource: California ISO
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)
- EIA-860M Preliminary Monthly Electric Generator Inventory
- EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)
Around this plant
Nearby
within 25 km| Project | Kind | Away | MW |
|---|---|---|---|
| 888 Ross Data Center Filed | Large load | 13.1 km | |
| 7999 Gateway Solar Under construction | Solar | 15.8 km | 4.6 |
| Gateway#1&2 (Newark CA) Announced | Solar | 16.0 km | 1.1 |
| Waste Management Tri-Cities LFGTE Postponed | Biomass | 18.4 km | 4.8 |
| SV8 DATA CENTER Unknown | Large load | 19.0 km | |
| VANTAGE DATA CENTERS MANAGEMENT CO , LLC Unknown | Large load | 19.1 km | |
| EDGECORE DATA CENTER MECP1 SANTA CLARA 1 PROJECT Unknown | Large load | 19.3 km | |
| Edgecore -3580 Filed | Large load | 19.3 km | |
| PRIME DATA CENTERS Built | Large load | 20.1 km | |
| 1200 Memorex Skybox Data Center Filed | Large load | 20.6 km | |
| Kifer BESS 1 Under construction | Storage | 20.7 km | 50 |
| 4054 Digital Realty Built | Large load | 21.0 km | |
| SKYBOX DATA CENTER Built | Large load | 21.2 km | |
| Ameresco Ox Mountain Filed | Biomass | 21.2 km | 3 |
| Fremont CA AutoFactory Under construction | Solar | 21.6 km | 3.8 |
| LBA Data Center West Filed | Large load | 22.0 km | |
| SJC02 & SJC03 DATA CENTER Unknown | Large load | 22.1 km | |
| HAYWARD DATA CENTER Unknown | Large load | 22.5 km |
Sources FAA OE/AAA · EIA-860M · EPA ICIS-NPDES · EPA ICIS-Air · CAISO