Loma Linda University Cogen
- Combustion
- Wind & solar
- Bioenergy
- In development
- Under construction
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Wind & solar
- Bioenergy
- In development
- Under construction
- Operating
Loma Linda University Cogen: location and 17 exact-grade projects within 15 mi. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Loma Linda University Cogen
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 55% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1986
- Net generation, 2025
- 63,575 MWh
- Grid
- 66 kV to Southern California Edison Co (CISO)
- Location
- San Bernardino County, California
- Operated by
- Loma Linda UniversitySourceEIA-860M Preliminary Monthly Electric Generator Inventory
Output
- Gas
- Oil
Details
Who’s behind it
- Owner
- Loma Linda UniversitySource100.0%, EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT), as of Dec 31, 2023
Interested in this project?
- Technology
- Gas, combustion turbine source: “Natural Gas Fired Combustion Turbine”
- Age
- 40 years since 1986
- Unused energy
- 51 GWh 2025Unused energyA lead, not a guarantee: MW × hours × (1 − capacity factor) for the latest year (EIA-923), gas, coal and oil plants only. Air-permit run-hour caps, heat rate (cost to run) and capacity-market or reliability obligations can rule it out.
- Heat rate
- 13,353 Btu/kWh 2025
All 7 attributes from EIA-860M Preliminary Monthly Electric Generator Inventory
| Attribute | Value |
|---|---|
| EPA greenhouse gas reporting (GHGRP) |
|
| Eia status |
|
| Fuel burned (MMBtu), 2025 | 848,895 |
| Capacity factor, 2025 | 0.554 |
| Heat rate (Btu/kWh), 2025 | 13,352.7 |
| Net generation (MWh), 2025 | 63,575 |
| Balancing authority code | CISO |
Retirement
EIA-860M September 2026StatusSome generators have retired; the rest of the plant is still in service. As of EIA-860M for September 2026.- Capacity retired
- 1.2 MW
- Generators retired
- 1
- Capacity still in service
- 13.1 MW
| Generator | Technology | Nameplate | State | Date |
|---|---|---|---|---|
| GEN3 | Natural Gas Fired Combined Cycle | 1.2 MW | Retired | July 2014 |
Grid
EIA-860 2025Grid fieldsAs the plant reported them to EIA-860 for 2025 (Schedule 2).- Grid voltage at the plant
- 66 kV
- Transmission or distribution system owner
- Southern California Edison Co
- Balancing authority
- California Independent System Operator
- NERC region
- WECC
Transmission lines within 15 mi (10)
Can the connection be reused?
A plant that retires usually leaves its substation, transmission connection and interconnection agreement behind, and those may be reusable by a new project at the same site. FERC Order No. 845 lets an interconnection customer use surplus interconnection service at an existing site, and some transmission providers' tariffs let a replacement resource take over a retiring unit's interconnection service, usually within a set time after the retirement. Whether any such right still exists here, who holds it and on what terms depends on the owner, the transmission provider and timing; this page does not establish any of that.
Timeline
- Stated Unit GEN3 scheduled to retire, 1.2 MW · EIA-860M
- In service · EIA-860M
Sources
5 sourcesSources EIA-860M · LBNL · EIA · EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT) · EIA-860M Preliminary Monthly Electric Generator Inventory
Sources
- EIA-860M
- LBNLYin, Nait Belaid & Heleno (2026), Lawrence Berkeley National Laboratory, OEDI, CC BY 4.0: A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024. Modified by Inframation: HIFLD-side fields only, names re-cased, coordinates rounded.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)
- EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)
- EIA-860M Preliminary Monthly Electric Generator Inventory
Around this plant
Nearby
within 15 mi| Project | Kind | Away | MW |
|---|---|---|---|
| SunE Redlands Postponed | Solar | 1.7 mi | 1.5 |
| Solar Photovoltaic Project #28 Postponed | Solar | 3.4 mi | 0.5 |
| Redlands DC 9 - sline609 Under construction | Solar + storage | 3.4 mi | 5 |
| Solar Photovoltaic Project #20 Postponed | Solar | 3.7 mi | 3.5 |
| Energy Center Announced | Gas, combustion turbine | 4.9 mi | 0.9 |
| Solar Photovoltaic Project #24 Postponed | Solar | 7.2 mi | 4 |
| CA Bloomington 2551 S Lilac Avenue Micro Under construction | Solar + storage | 7.4 mi | 3 |
| CA Riverside 2356 Fleetwood Dr. Under construction | Solar + storage | 8.0 mi | 4 |
| RCWMD Badlands Landfill Gas Project Postponed | Biomass | 9.5 mi | 1.2 |
| OES Biogas Power Under construction | Biomass | 10.2 mi | 2.6 |
| Solar Photovoltaic Project #30 Postponed | Solar | 10.2 mi | 1.5 |
| Solar Photovoltaic Project #25 Postponed | Solar | 11.4 mi | 4.5 |
| Solar Photovoltaic Project #27 Postponed | Solar | 11.4 mi | 1 |
| Amazon - Moreno Valley Postponed | Solar | 12.3 mi | 2.2 |
| Perris DC 5 - sline015 Under construction | Solar | 13.9 mi | 1.6 |
| Solar Photovoltaic Project #17 Postponed | Solar | 14.7 mi | 0.5 |
| Solar Photovoltaic Project #14 Postponed | Solar | 14.9 mi | 1.5 |
Sources EIA-860M